{"id":11016,"date":"2026-03-05T05:45:42","date_gmt":"2026-03-05T05:45:42","guid":{"rendered":"https:\/\/bootsshopbodensee.com\/shop\/kohler-kg100-100kw-generator-120-240v-1-phase-ca-ma-steel-enclosure\/"},"modified":"2026-04-08T16:05:03","modified_gmt":"2026-04-08T16:05:03","slug":"kohler-kg100-100kw-generator-liquid-cooled-347-600-volt-3-phase","status":"publish","type":"product","link":"https:\/\/bootsshopbodensee.com\/it\/shop\/kohler-kg100-100kw-generator-liquid-cooled-347-600-volt-3-phase\/","title":{"rendered":"Generatore Kohler KG100 da 100 kW raffreddato a liquido, 347\/600 Volt, trifase, involucro in alluminio | KG100R-QS6"},"content":{"rendered":"<h2 data-section-id=\"olvrvo\" data-start=\"690\" data-end=\"755\"><strong>Generatore Kohler KG100 100kW raffreddato a liquido 347\/600 Volt trifase<\/strong><\/h2>\n<p data-start=\"774\" data-end=\"1166\">IL <strong data-start=\"778\" data-end=\"845\">Generatore Kohler KG100 100kW raffreddato a liquido 347\/600 Volt trifase<\/strong> is engineered to deliver dependable standby power for commercial facilities, industrial buildings, and critical infrastructure. Designed with a powerful 6.2-liter turbocharged V-8 engine, this generator ensures stable electricity during outages while maintaining excellent voltage regulation and low harmonic distortion.<\/p>\n<p data-start=\"1168\" data-end=\"1564\">Reliable standby power systems are essential for businesses that cannot afford downtime. Hospitals, factories, data centers, and large commercial buildings rely on high-capacity generators that start automatically and maintain power quality under heavy loads. The Kohler KG100 was built for these environments, combining industrial-grade engineering with advanced monitoring and control features.<\/p>\n<p data-start=\"1566\" data-end=\"1906\">With a wind-rated aluminum enclosure capable of withstanding extreme conditions and a quiet operation level of only 65 dBA, the generator provides both durability and comfort. In addition, the system meets major regulatory and safety standards including UL-2200 and NFPA 110 Level 1 compatibility when installed with the proper accessories.<\/p>\n<p data-start=\"1908\" data-end=\"2102\">Facilities requiring high-capacity <strong data-start=\"1943\" data-end=\"1973\">600V three phase generator<\/strong> solutions often choose Kohler because of its reputation for engineering excellence, long service life, and superior reliability.<\/p>\n<hr data-start=\"2104\" data-end=\"2107\" \/>\n<h2 data-section-id=\"9n10hw\" data-start=\"2109\" data-end=\"2184\">Kohler KG100 100kW Generator Liquid Cooled 347\/600 Volt 3 Phase Overview<\/h2>\n<p data-start=\"2186\" data-end=\"2446\">IL <strong data-start=\"2190\" data-end=\"2257\">Generatore Kohler KG100 100kW raffreddato a liquido 347\/600 Volt trifase<\/strong> is a high-performance standby generator designed for demanding electrical systems. Its advanced design ensures that critical equipment continues operating even during major power failures.<\/p>\n<p data-start=\"2448\" data-end=\"2478\">Key system highlights include:<\/p>\n<ul data-start=\"2480\" data-end=\"2885\">\n<li data-section-id=\"mf8geb\" data-start=\"2480\" data-end=\"2506\">\n<p data-start=\"2482\" data-end=\"2506\">100kW rated output power<\/p>\n<\/li>\n<li data-section-id=\"wcw35b\" data-start=\"2507\" data-end=\"2554\">\n<p data-start=\"2509\" data-end=\"2554\">347\/600 Volt 3-phase electrical configuration<\/p>\n<\/li>\n<li data-section-id=\"tes6a7\" data-start=\"2555\" data-end=\"2592\">\n<p data-start=\"2557\" data-end=\"2592\">Turbocharged aftercooled V-8 engine<\/p>\n<\/li>\n<li data-section-id=\"o71m92\" data-start=\"2593\" data-end=\"2638\">\n<p data-start=\"2595\" data-end=\"2638\">Liquid cooled system for extended operation<\/p>\n<\/li>\n<li data-section-id=\"1ch4qtx\" data-start=\"2639\" data-end=\"2680\">\n<p data-start=\"2641\" data-end=\"2680\">Quiet operation at approximately 65 dBA<\/p>\n<\/li>\n<li data-section-id=\"uvwdh9\" data-start=\"2681\" data-end=\"2718\">\n<p data-start=\"2683\" data-end=\"2718\">Aluminum sound-attenuated enclosure<\/p>\n<\/li>\n<li data-section-id=\"xnry6y\" data-start=\"2719\" data-end=\"2755\">\n<p data-start=\"2721\" data-end=\"2755\">Advanced APM402 digital controller<\/p>\n<\/li>\n<li data-section-id=\"150cim0\" data-start=\"2756\" data-end=\"2801\">\n<p data-start=\"2758\" data-end=\"2801\">Compatible with Natural Gas or Propane fuel<\/p>\n<\/li>\n<li data-section-id=\"pq95zh\" data-start=\"2802\" data-end=\"2838\">\n<p data-start=\"2804\" data-end=\"2838\">UL-2200 certified generator system<\/p>\n<\/li>\n<li data-section-id=\"1rzo9f6\" data-start=\"2839\" data-end=\"2885\">\n<p data-start=\"2841\" data-end=\"2885\">NFPA 110 Level 1 capability with accessories<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2887\" data-end=\"3043\">The generator accepts rated load in one step and maintains extremely stable voltage output, which is critical for protecting sensitive electronic equipment.<\/p>\n<p data-start=\"3045\" data-end=\"3215\">Businesses requiring a <strong data-start=\"3068\" data-end=\"3099\">generatore di backup commerciale<\/strong> with proven durability often rely on Kohler systems because of their robust engineering and long operating history.<\/p>\n<hr data-start=\"3217\" data-end=\"3220\" \/>\n<h2 data-section-id=\"n4bp9\" data-start=\"3222\" data-end=\"3273\">Engine Performance and Liquid Cooling Technology<\/h2>\n<p data-start=\"3275\" data-end=\"3462\">Nel cuore del <strong data-start=\"3295\" data-end=\"3321\">Kohler 100kW generator<\/strong> is the Kohler KG6208TASD engine, a 6.2-liter turbocharged and aftercooled V-8 power unit designed specifically for standby power generation.<\/p>\n<h3 data-section-id=\"1l1s75y\" data-start=\"3464\" data-end=\"3489\">Engine specifications<\/h3>\n<ul data-start=\"3491\" data-end=\"3677\">\n<li data-section-id=\"fme79i\" data-start=\"3491\" data-end=\"3516\">\n<p data-start=\"3493\" data-end=\"3516\">Engine size: 6.2 liters<\/p>\n<\/li>\n<li data-section-id=\"9pnjsb\" data-start=\"3517\" data-end=\"3562\">\n<p data-start=\"3519\" data-end=\"3562\">Configuration: V-8 turbocharged aftercooled<\/p>\n<\/li>\n<li data-section-id=\"26bkl9\" data-start=\"3563\" data-end=\"3587\">\n<p data-start=\"3565\" data-end=\"3587\">Engine speed: 1800 RPM<\/p>\n<\/li>\n<li data-section-id=\"6fzvi2\" data-start=\"3588\" data-end=\"3619\">\n<p data-start=\"3590\" data-end=\"3619\">Cooling system: liquid cooled<\/p>\n<\/li>\n<li data-section-id=\"1m4dn5i\" data-start=\"3620\" data-end=\"3658\">\n<p data-start=\"3622\" data-end=\"3658\">Fuel options: natural gas or propane<\/p>\n<\/li>\n<li data-section-id=\"1cq76ki\" data-start=\"3659\" data-end=\"3677\">\n<p data-start=\"3661\" data-end=\"3677\">Frequenza: 60 Hz<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3679\" data-end=\"3900\">Liquid cooling is one of the most important advantages of this <strong data-start=\"3742\" data-end=\"3777\">generatore di riserva raffreddato a liquido<\/strong>. Unlike air-cooled systems, liquid cooling maintains stable temperatures even during extended operation under heavy loads.<\/p>\n<p data-start=\"3902\" data-end=\"3937\">Benefits of liquid cooling include:<\/p>\n<ul data-start=\"3939\" data-end=\"4074\">\n<li data-section-id=\"d9kcfl\" data-start=\"3939\" data-end=\"3963\">\n<p data-start=\"3941\" data-end=\"3963\">Longer engine lifespan<\/p>\n<\/li>\n<li data-section-id=\"vatdc6\" data-start=\"3964\" data-end=\"3983\">\n<p data-start=\"3966\" data-end=\"3983\">Higher efficiency<\/p>\n<\/li>\n<li data-section-id=\"1mimsup\" data-start=\"3984\" data-end=\"4010\">\n<p data-start=\"3986\" data-end=\"4010\">Improved noise reduction<\/p>\n<\/li>\n<li data-section-id=\"4gefgz\" data-start=\"4011\" data-end=\"4039\">\n<p data-start=\"4013\" data-end=\"4039\">Better temperature control<\/p>\n<\/li>\n<li data-section-id=\"va2uu5\" data-start=\"4040\" data-end=\"4074\">\n<p data-start=\"4042\" data-end=\"4074\">Continuous heavy-load capability<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4076\" data-end=\"4179\">This technology allows the generator to maintain consistent performance even during long power outages.<\/p>\n<hr data-start=\"4181\" data-end=\"4184\" \/>\n<h2 data-section-id=\"1t0hlpw\" data-start=\"4186\" data-end=\"4234\">Regolazione avanzata della tensione e qualit\u00e0 dell&#039;energia<\/h2>\n<p data-start=\"4236\" data-end=\"4466\">Power quality is a critical requirement for industrial facilities and modern electronic equipment. The <strong data-start=\"4339\" data-end=\"4406\">Generatore Kohler KG100 100kW raffreddato a liquido 347\/600 Volt trifase<\/strong> provides industry-leading voltage and frequency regulation.<\/p>\n<h3 data-section-id=\"1w99rvk\" data-start=\"4468\" data-end=\"4507\">Key electrical performance features<\/h3>\n<ul data-start=\"4509\" data-end=\"4685\">\n<li data-section-id=\"7dnyqx\" data-start=\"4509\" data-end=\"4541\">\n<p data-start=\"4511\" data-end=\"4541\">Frequency regulation within 1%<\/p>\n<\/li>\n<li data-section-id=\"1pooty0\" data-start=\"4542\" data-end=\"4574\">\n<p data-start=\"4544\" data-end=\"4574\">Hybrid voltage regulator \u00b10.5%<\/p>\n<\/li>\n<li data-section-id=\"bqievg\" data-start=\"4575\" data-end=\"4617\">\n<p data-start=\"4577\" data-end=\"4617\">Total harmonic distortion less than 3.2%<\/p>\n<\/li>\n<li data-section-id=\"16h9xbd\" data-start=\"4618\" data-end=\"4655\">\n<p data-start=\"4620\" data-end=\"4655\">Brushless rotating field alternator<\/p>\n<\/li>\n<li data-section-id=\"14yh5pj\" data-start=\"4656\" data-end=\"4685\">\n<p data-start=\"4658\" data-end=\"4685\">Four-pole alternator design<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4687\" data-end=\"4746\">Low harmonic distortion protects sensitive devices such as:<\/p>\n<ul data-start=\"4748\" data-end=\"4862\">\n<li data-section-id=\"k68k21\" data-start=\"4748\" data-end=\"4767\">\n<p data-start=\"4750\" data-end=\"4767\">medical equipment<\/p>\n<\/li>\n<li data-section-id=\"a9fdb1\" data-start=\"4768\" data-end=\"4794\">\n<p data-start=\"4770\" data-end=\"4794\">servers and data centers<\/p>\n<\/li>\n<li data-section-id=\"1bctlba\" data-start=\"4795\" data-end=\"4826\">\n<p data-start=\"4797\" data-end=\"4826\">industrial automation systems<\/p>\n<\/li>\n<li data-section-id=\"1jxy4as\" data-start=\"4827\" data-end=\"4862\">\n<p data-start=\"4829\" data-end=\"4862\">telecommunications infrastructure<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4864\" data-end=\"4985\">This makes the generator ideal for <strong data-start=\"4899\" data-end=\"4931\">industrial standby generator<\/strong> applications where electrical stability is essential.<\/p>\n<hr data-start=\"4987\" data-end=\"4990\" \/>\n<h2 data-section-id=\"2dgpx6\" data-start=\"4992\" data-end=\"5030\">APM402 Digital Generator Controller<\/h2>\n<p data-start=\"5032\" data-end=\"5154\">The generator includes the advanced Kohler APM402 controller, which provides complete monitoring and control capabilities.<\/p>\n<h3 data-section-id=\"19kwcuk\" data-start=\"5156\" data-end=\"5183\">Controller capabilities<\/h3>\n<ul data-start=\"5185\" data-end=\"5385\">\n<li data-section-id=\"1gbvg7u\" data-start=\"5185\" data-end=\"5222\">\n<p data-start=\"5187\" data-end=\"5222\">Digital display and menu navigation<\/p>\n<\/li>\n<li data-section-id=\"1q5wvr9\" data-start=\"5223\" data-end=\"5260\">\n<p data-start=\"5225\" data-end=\"5260\">Real-time generator data monitoring<\/p>\n<\/li>\n<li data-section-id=\"vpxvtb\" data-start=\"5261\" data-end=\"5292\">\n<p data-start=\"5263\" data-end=\"5292\">System diagnostics and alerts<\/p>\n<\/li>\n<li data-section-id=\"6dn1a4\" data-start=\"5293\" data-end=\"5326\">\n<p data-start=\"5295\" data-end=\"5326\">Remote communication capability<\/p>\n<\/li>\n<li data-section-id=\"1n48vjn\" data-start=\"5327\" data-end=\"5352\">\n<p data-start=\"5329\" data-end=\"5352\">Modbus protocol support<\/p>\n<\/li>\n<li data-section-id=\"3punf\" data-start=\"5353\" data-end=\"5385\">\n<p data-start=\"5355\" data-end=\"5385\">Alternator overload protection<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"5387\" data-end=\"5508\">Operators can easily monitor generator status, voltage output, and system alerts directly from the digital control panel.<\/p>\n<p data-start=\"5510\" data-end=\"5627\">This smart controller makes the generator easier to maintain and manage compared with traditional mechanical systems.<\/p>\n<hr data-start=\"5629\" data-end=\"5632\" \/>\n<h2 data-section-id=\"4o1sxc\" data-start=\"5634\" data-end=\"5672\">Aluminum Sound-Attenuated Enclosure<\/h2>\n<p data-start=\"5674\" data-end=\"5879\">Durability and weather resistance are essential for outdoor generator installations. The Kohler KG100 uses a heavy-duty aluminum enclosure designed to protect internal components from environmental damage.<\/p>\n<h3 data-section-id=\"p9vwdg\" data-start=\"5881\" data-end=\"5905\">Enclosure advantages<\/h3>\n<ul data-start=\"5907\" data-end=\"6056\">\n<li data-section-id=\"njltkb\" data-start=\"5907\" data-end=\"5930\">\n<p data-start=\"5909\" data-end=\"5930\">Wind rated to 186 MPH<\/p>\n<\/li>\n<li data-section-id=\"b0hq3f\" data-start=\"5931\" data-end=\"5974\">\n<p data-start=\"5933\" data-end=\"5974\">Corrosion-resistant aluminum construction<\/p>\n<\/li>\n<li data-section-id=\"17mjvmm\" data-start=\"5975\" data-end=\"6005\">\n<p data-start=\"5977\" data-end=\"6005\">Integrated sound attenuation<\/p>\n<\/li>\n<li data-section-id=\"goqisx\" data-start=\"6006\" data-end=\"6029\">\n<p data-start=\"6008\" data-end=\"6029\">Secure locking panels<\/p>\n<\/li>\n<li data-section-id=\"6nir7i\" data-start=\"6030\" data-end=\"6056\">\n<p data-start=\"6032\" data-end=\"6056\">Weather-resistant design<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"6058\" data-end=\"6220\">Despite its powerful output, the generator operates at approximately <strong data-start=\"6127\" data-end=\"6137\">65 dBA<\/strong>, making it one of the quieter options in the <strong data-start=\"6183\" data-end=\"6210\">100kW standby generator<\/strong> category.<\/p>\n<p data-start=\"6222\" data-end=\"6344\">This makes it suitable for installation near commercial buildings or residential areas where noise restrictions may apply.<\/p>\n<hr data-start=\"6346\" data-end=\"6349\" \/>\n<h2 data-section-id=\"mt35fl\" data-start=\"6351\" data-end=\"6382\">Fuel Options and Consumption<\/h2>\n<p data-start=\"6384\" data-end=\"6514\">The generator operates on either natural gas or propane, giving businesses flexibility depending on available fuel infrastructure.<\/p>\n<h3 data-section-id=\"5dow93\" data-start=\"6516\" data-end=\"6543\">Consumo di gas naturale<\/h3>\n<ul data-start=\"6545\" data-end=\"6619\">\n<li data-section-id=\"1wxiv3b\" data-start=\"6545\" data-end=\"6581\">\n<p data-start=\"6547\" data-end=\"6581\">Half load: 946 cubic feet per hour<\/p>\n<\/li>\n<li data-section-id=\"lsgvot\" data-start=\"6582\" data-end=\"6619\">\n<p data-start=\"6584\" data-end=\"6619\">Full load: 1473 cubic feet per hour<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"do2ed0\" data-start=\"6621\" data-end=\"6644\">Consumo di propano<\/h3>\n<ul data-start=\"6646\" data-end=\"6716\">\n<li data-section-id=\"1r4zwtp\" data-start=\"6646\" data-end=\"6681\">\n<p data-start=\"6648\" data-end=\"6681\">Half load: 11.07 gallons per hour<\/p>\n<\/li>\n<li data-section-id=\"1a7imp7\" data-start=\"6682\" data-end=\"6716\">\n<p data-start=\"6684\" data-end=\"6716\">Full load: 18.8 gallons per hour<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"6718\" data-end=\"6793\">Fuel flexibility makes the system suitable for many environments including:<\/p>\n<ul data-start=\"6795\" data-end=\"6908\">\n<li data-section-id=\"17u42nr\" data-start=\"6795\" data-end=\"6818\">\n<p data-start=\"6797\" data-end=\"6818\">commercial facilities<\/p>\n<\/li>\n<li data-section-id=\"neht67\" data-start=\"6819\" data-end=\"6830\">\n<p data-start=\"6821\" data-end=\"6830\">hospitals<\/p>\n<\/li>\n<li data-section-id=\"1ko6kzg\" data-start=\"6831\" data-end=\"6853\">\n<p data-start=\"6833\" data-end=\"6853\">manufacturing plants<\/p>\n<\/li>\n<li data-section-id=\"1ssw7ba\" data-start=\"6854\" data-end=\"6880\">\n<p data-start=\"6856\" data-end=\"6880\">emergency infrastructure<\/p>\n<\/li>\n<li data-section-id=\"tkyuqu\" data-start=\"6881\" data-end=\"6908\">\n<p data-start=\"6883\" data-end=\"6908\">large residential estates<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"6910\" data-end=\"7041\">Many organizations prefer a <strong data-start=\"6938\" data-end=\"6971\">generatore di emergenza a gas naturale<\/strong> because gas supply lines provide continuous fuel during long outages.<\/p>\n<hr data-start=\"7043\" data-end=\"7046\" \/>\n<h2 data-section-id=\"1bp4abo\" data-start=\"7048\" data-end=\"7087\">Compliance and Safety Certifications<\/h2>\n<p data-start=\"7089\" data-end=\"7247\">IL <strong data-start=\"7093\" data-end=\"7160\">Generatore Kohler KG100 100kW raffreddato a liquido 347\/600 Volt trifase<\/strong> meets strict safety and operational standards required for professional installations.<\/p>\n<p data-start=\"7249\" data-end=\"7282\">Important certifications include:<\/p>\n<ul data-start=\"7284\" data-end=\"7428\">\n<li data-section-id=\"1eznl0p\" data-start=\"7284\" data-end=\"7317\">\n<p data-start=\"7286\" data-end=\"7317\">UL-2200 listed generator system<\/p>\n<\/li>\n<li data-section-id=\"17q8vp5\" data-start=\"7318\" data-end=\"7361\">\n<p data-start=\"7320\" data-end=\"7361\">EPA certified for stationary applications<\/p>\n<\/li>\n<li data-section-id=\"y1l8g8\" data-start=\"7362\" data-end=\"7394\">\n<p data-start=\"7364\" data-end=\"7394\">NFPA 110 Level 1 compatibility<\/p>\n<\/li>\n<li data-section-id=\"u5vxx6\" data-start=\"7395\" data-end=\"7428\">\n<p data-start=\"7397\" data-end=\"7428\">NEC prime mover shutdown switch<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"7430\" data-end=\"7567\">These certifications ensure the generator meets regulatory requirements for critical facilities such as hospitals and emergency services.<\/p>\n<hr data-start=\"7569\" data-end=\"7572\" \/>\n<h2 data-section-id=\"z5y173\" data-start=\"7574\" data-end=\"7605\">Specifiche tecniche chiave<\/h2>\n<p data-start=\"7607\" data-end=\"8040\"><strong data-start=\"7607\" data-end=\"7617\">Modello:<\/strong> KG100R-QS6<br data-start=\"7628\" data-end=\"7631\" \/><strong data-start=\"7631\" data-end=\"7647\">Potenza nominale:<\/strong> 100 kW<br data-start=\"7654\" data-end=\"7657\" \/><strong data-start=\"7657\" data-end=\"7669\">voltaggio:<\/strong> 347\/600 Volt trifase<br data-start=\"7691\" data-end=\"7694\" \/><strong data-start=\"7694\" data-end=\"7709\">Ampere nominali:<\/strong> 121 Ampere<br data-start=\"7718\" data-end=\"7721\" \/><strong data-start=\"7721\" data-end=\"7735\">Frequenza:<\/strong> 60 Hz<br data-start=\"7741\" data-end=\"7744\" \/><strong data-start=\"7744\" data-end=\"7761\">Engine Speed:<\/strong> 1800 giri\/min<br data-start=\"7770\" data-end=\"7773\" \/><strong data-start=\"7773\" data-end=\"7792\">Sistema di raffreddamento:<\/strong> Liquid cooled<br data-start=\"7806\" data-end=\"7809\" \/><strong data-start=\"7809\" data-end=\"7829\">Alternator Type:<\/strong> Brushless rotating field<br data-start=\"7854\" data-end=\"7857\" \/><strong data-start=\"7857\" data-end=\"7871\">Enclosure:<\/strong> Aluminum sound enclosure<br data-start=\"7896\" data-end=\"7899\" \/><strong data-start=\"7899\" data-end=\"7915\">Livello di rumore:<\/strong> 65 dBA<br data-start=\"7922\" data-end=\"7925\" \/><strong data-start=\"7925\" data-end=\"7939\">Tipo di carburante:<\/strong> Natural Gas or Propane<br data-start=\"7962\" data-end=\"7965\" \/><strong data-start=\"7965\" data-end=\"7989\">Battery Requirement:<\/strong> 12-Volt 650 CCA<br data-start=\"8005\" data-end=\"8008\" \/><strong data-start=\"8008\" data-end=\"8029\">Mainline Breaker:<\/strong> 125 Ampere<\/p>\n<h3 data-section-id=\"bpec4l\" data-start=\"8042\" data-end=\"8056\">Dimensioni<\/h3>\n<ul data-start=\"8058\" data-end=\"8129\">\n<li data-section-id=\"1sc69w8\" data-start=\"8058\" data-end=\"8082\">\n<p data-start=\"8060\" data-end=\"8082\">Length: 138.8 inches<\/p>\n<\/li>\n<li data-section-id=\"11s05v9\" data-start=\"8083\" data-end=\"8105\">\n<p data-start=\"8085\" data-end=\"8105\">Width: 45.4 inches<\/p>\n<\/li>\n<li data-section-id=\"qe9n67\" data-start=\"8106\" data-end=\"8129\">\n<p data-start=\"8108\" data-end=\"8129\">Height: 65.5 inches<\/p>\n<\/li>\n<\/ul>\n<h3 data-section-id=\"mjw76u\" data-start=\"8131\" data-end=\"8141\">Peso<\/h3>\n<ul data-start=\"8143\" data-end=\"8156\">\n<li data-section-id=\"i5zevz\" data-start=\"8143\" data-end=\"8156\">\n<p data-start=\"8145\" data-end=\"8156\">3340 pounds<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"8158\" data-end=\"8161\" \/>\n<h2 data-section-id=\"170cjrq\" data-start=\"8163\" data-end=\"8210\">Installation Requirements and Best Practices<\/h2>\n<p data-start=\"8212\" data-end=\"8286\">Proper installation ensures the generator performs safely and efficiently.<\/p>\n<h3 data-section-id=\"rck9ds\" data-start=\"8288\" data-end=\"8320\">Installation recommendations<\/h3>\n<ol data-start=\"8322\" data-end=\"8588\">\n<li data-section-id=\"1o6qg0u\" data-start=\"8322\" data-end=\"8371\">\n<p data-start=\"8325\" data-end=\"8371\">Prepare a solid mounting pad or concrete base.<\/p>\n<\/li>\n<li data-section-id=\"rgh9ts\" data-start=\"8372\" data-end=\"8438\">\n<p data-start=\"8375\" data-end=\"8438\">Install automatic transfer switch compatible with 600V systems.<\/p>\n<\/li>\n<li data-section-id=\"l5ehng\" data-start=\"8439\" data-end=\"8486\">\n<p data-start=\"8442\" data-end=\"8486\">Ensure proper fuel line sizing and pressure.<\/p>\n<\/li>\n<li data-section-id=\"nggrrb\" data-start=\"8487\" data-end=\"8540\">\n<p data-start=\"8490\" data-end=\"8540\">Provide adequate ventilation around the enclosure.<\/p>\n<\/li>\n<li data-section-id=\"1j48b4q\" data-start=\"8541\" data-end=\"8588\">\n<p data-start=\"8544\" data-end=\"8588\">Install remote monitoring for system alerts.<\/p>\n<\/li>\n<\/ol>\n<p data-start=\"8590\" data-end=\"8723\">Professional installation is strongly recommended for <strong data-start=\"8644\" data-end=\"8675\">generatore di backup commerciale<\/strong> systems due to high voltage and power capacity.<\/p>\n<hr data-start=\"8725\" data-end=\"8728\" \/>\n<h2 data-section-id=\"1fj4eh7\" data-start=\"8730\" data-end=\"8788\">Expert Insight: Why Businesses Choose Kohler Generators<\/h2>\n<p data-start=\"8790\" data-end=\"8934\">Power generation experts often recommend Kohler generators for mission-critical operations because of their reliability and engineering quality.<\/p>\n<p data-start=\"8936\" data-end=\"8990\">Several factors contribute to their strong reputation:<\/p>\n<ul data-start=\"8992\" data-end=\"9144\">\n<li data-section-id=\"1kp0bzk\" data-start=\"8992\" data-end=\"9026\">\n<p data-start=\"8994\" data-end=\"9026\">proven industrial engine designs<\/p>\n<\/li>\n<li data-section-id=\"16xso2z\" data-start=\"9027\" data-end=\"9056\">\n<p data-start=\"9029\" data-end=\"9056\">excellent voltage stability<\/p>\n<\/li>\n<li data-section-id=\"xl2yns\" data-start=\"9057\" data-end=\"9081\">\n<p data-start=\"9059\" data-end=\"9081\">long warranty coverage<\/p>\n<\/li>\n<li data-section-id=\"vvbxbi\" data-start=\"9082\" data-end=\"9109\">\n<p data-start=\"9084\" data-end=\"9109\">strong parts availability<\/p>\n<\/li>\n<li data-section-id=\"k71ujh\" data-start=\"9110\" data-end=\"9144\">\n<p data-start=\"9112\" data-end=\"9144\">advanced digital control systems<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"9146\" data-end=\"9597\">Facilities managers frequently compare different <a href=\"https:\/\/en.wikipedia.org\/wiki\/Generator\" target=\"_blank\" rel=\"noopener\">generatore<\/a> models before selecting a system. For example, when evaluating high-capacity standby power systems, many customers also consider units like the<br data-start=\"9348\" data-end=\"9351\" \/><a href=\"https:\/\/bootsshopbodensee.com\/it\/shop\/kohler-150kw-generator-120-240-volt-single-phase-steel-enclosure\/\">Kohler 150kW Generator 120\/240 Volt Single Phase Steel Enclosure<\/a><br data-start=\"9530\" data-end=\"9533\" \/>which offers a larger power output for heavier electrical loads.<\/p>\n<p data-start=\"9599\" data-end=\"9732\">Comparing models helps determine whether a <strong data-start=\"9642\" data-end=\"9669\">100kW standby generator<\/strong> or a larger system is better suited for a particular building.<\/p>\n<hr data-start=\"9734\" data-end=\"9737\" \/>\n<h2 data-section-id=\"z2c4qf\" data-start=\"9739\" data-end=\"9794\">Maintenance Tips for Long-Term Generator Reliability<\/h2>\n<p data-start=\"9796\" data-end=\"9875\">Regular maintenance ensures long operating life and dependable emergency power.<\/p>\n<h3 data-section-id=\"1shxtmj\" data-start=\"9877\" data-end=\"9908\">Essential maintenance tasks<\/h3>\n<ul data-start=\"9910\" data-end=\"10098\">\n<li data-section-id=\"127wydh\" data-start=\"9910\" data-end=\"9957\">\n<p data-start=\"9912\" data-end=\"9957\">Inspect engine oil and coolant levels monthly<\/p>\n<\/li>\n<li data-section-id=\"1onqaac\" data-start=\"9958\" data-end=\"9998\">\n<p data-start=\"9960\" data-end=\"9998\">Test generator under load periodically<\/p>\n<\/li>\n<li data-section-id=\"w3gfka\" data-start=\"9999\" data-end=\"10035\">\n<p data-start=\"10001\" data-end=\"10035\">Replace air filters as recommended<\/p>\n<\/li>\n<li data-section-id=\"1xxxtq9\" data-start=\"10036\" data-end=\"10065\">\n<p data-start=\"10038\" data-end=\"10065\">Inspect fuel supply systems<\/p>\n<\/li>\n<li data-section-id=\"ap9mls\" data-start=\"10066\" data-end=\"10098\">\n<p data-start=\"10068\" data-end=\"10098\">Check battery health regularly<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"10100\" data-end=\"10211\">A preventative maintenance schedule significantly reduces the risk of unexpected failures during power outages.<\/p>\n<p data-start=\"10213\" data-end=\"10289\">Most commercial operators perform maintenance every 200\u2013400 operating hours.<\/p>\n<hr data-start=\"10291\" data-end=\"10294\" \/>\n<h2 data-section-id=\"1ws3h3g\" data-start=\"10296\" data-end=\"10351\">Practical Applications for a 100kW Standby Generator<\/h2>\n<p data-start=\"10353\" data-end=\"10502\">IL <strong data-start=\"10357\" data-end=\"10424\">Generatore Kohler KG100 100kW raffreddato a liquido 347\/600 Volt trifase<\/strong> is ideal for medium to large facilities that require dependable backup power.<\/p>\n<p data-start=\"10504\" data-end=\"10532\">Common applications include:<\/p>\n<ul data-start=\"10534\" data-end=\"10723\">\n<li data-section-id=\"1ko6kzg\" data-start=\"10534\" data-end=\"10556\">\n<p data-start=\"10536\" data-end=\"10556\">manufacturing plants<\/p>\n<\/li>\n<li data-section-id=\"16370s5\" data-start=\"10557\" data-end=\"10591\">\n<p data-start=\"10559\" data-end=\"10591\">hospitals and healthcare centers<\/p>\n<\/li>\n<li data-section-id=\"e0ida8\" data-start=\"10592\" data-end=\"10625\">\n<p data-start=\"10594\" data-end=\"10625\">hotels and commercial complexes<\/p>\n<\/li>\n<li data-section-id=\"ilqlyo\" data-start=\"10626\" data-end=\"10650\">\n<p data-start=\"10628\" data-end=\"10650\">large office buildings<\/p>\n<\/li>\n<li data-section-id=\"1jxy4as\" data-start=\"10651\" data-end=\"10686\">\n<p data-start=\"10653\" data-end=\"10686\">telecommunications infrastructure<\/p>\n<\/li>\n<li data-section-id=\"1ms9h2x\" data-start=\"10687\" data-end=\"10723\">\n<p data-start=\"10689\" data-end=\"10723\">agricultural processing facilities<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"10725\" data-end=\"10871\">A <strong data-start=\"10727\" data-end=\"10757\">600V three phase generator<\/strong> is especially valuable in industrial environments where heavy machinery requires high-voltage power distribution.<\/p>\n<hr data-start=\"10873\" data-end=\"10876\" \/>\n<h2 data-section-id=\"8dtpi\" data-start=\"10878\" data-end=\"10891\">Conclusione<\/h2>\n<p data-start=\"10893\" data-end=\"11262\">IL <strong data-start=\"10897\" data-end=\"10964\">Generatore Kohler KG100 100kW raffreddato a liquido 347\/600 Volt trifase<\/strong> delivers reliable standby power for commercial and industrial environments where electrical continuity is essential. Its powerful turbocharged V-8 engine, advanced APM402 digital controller, and robust aluminum enclosure combine to create a generator capable of performing in demanding conditions.<\/p>\n<p data-start=\"11264\" data-end=\"11613\">With excellent voltage regulation, low harmonic distortion, and support for natural gas or propane fuel systems, the generator offers both flexibility and efficiency. Businesses requiring a dependable <strong data-start=\"11465\" data-end=\"11492\">100kW standby generator<\/strong> will benefit from the durability, engineering quality, and advanced technology that Kohler incorporates into every unit.<\/p>\n<p data-start=\"11615\" data-end=\"11785\">When power reliability is critical, investing in a high-quality industrial generator like the Kohler KG100 ensures operations remain protected against unexpected outages.<\/p>\n<hr data-start=\"11787\" data-end=\"11790\" \/>\n<h1 data-section-id=\"1mpc0g\" data-start=\"11792\" data-end=\"11797\">FAQ<\/h1>\n<h3 data-section-id=\"16nuzvd\" data-start=\"11799\" data-end=\"11858\">What is the power output of the Kohler KG100 generator?<\/h3>\n<p data-start=\"11859\" data-end=\"11986\">The Kohler KG100 produces 100 kilowatts of standby power, making it suitable for commercial and industrial backup applications.<\/p>\n<h3 data-section-id=\"ihwrau\" data-start=\"11988\" data-end=\"12045\">What voltage does the Kohler KG100 generator produce?<\/h3>\n<p data-start=\"12046\" data-end=\"12128\">The generator operates at 347\/600 volts in a three-phase electrical configuration.<\/p>\n<h3 data-section-id=\"bc6xsi\" data-start=\"12130\" data-end=\"12190\">What type of engine does the Kohler KG100 generator use?<\/h3>\n<p data-start=\"12191\" data-end=\"12296\">It uses a 6.2-liter turbocharged aftercooled V-8 engine designed for high-capacity standby power systems.<\/p>\n<h3 data-section-id=\"vcfjd6\" data-start=\"12298\" data-end=\"12342\">Can the Kohler KG100 run on natural gas?<\/h3>\n<p data-start=\"12343\" data-end=\"12408\">Yes. The generator can run on either natural gas or propane fuel.<\/p>\n<h3 data-section-id=\"edndcu\" data-start=\"12410\" data-end=\"12469\">Is the Kohler KG100 suitable for industrial facilities?<\/h3>\n<p data-start=\"12470\" data-end=\"12575\">Yes. Its 600V three-phase output and stable voltage regulation make it ideal for industrial environments.<\/p>\n<h3 data-section-id=\"aqta0x\" data-start=\"12577\" data-end=\"12620\">How loud is the Kohler KG100 generator?<\/h3>\n<p data-start=\"12621\" data-end=\"12692\">The generator operates at approximately 65 dBA during normal operation.<\/p>\n<h3 data-section-id=\"3lckn6\" data-start=\"12694\" data-end=\"12740\">What controller does the Kohler KG100 use?<\/h3>\n<p data-start=\"12741\" data-end=\"12837\">It uses the Kohler APM402 digital controller for monitoring, diagnostics, and system management.<\/p>\n<h3 data-section-id=\"1eoxb8p\" data-start=\"12839\" data-end=\"12897\">Does the Kohler KG100 generator meet safety standards?<\/h3>\n<p data-start=\"12898\" data-end=\"12991\">Yes. It is UL-2200 listed and can meet NFPA 110 Level 1 requirements when properly installed.<\/p>","protected":false},"excerpt":{"rendered":"<p><strong data-start=\"7607\" data-end=\"7617\">Modello:<\/strong> KG100R-QS6<br data-start=\"7628\" data-end=\"7631\" \/><strong data-start=\"7631\" data-end=\"7647\">Potenza nominale:<\/strong> 100 kW<br data-start=\"7654\" data-end=\"7657\" \/><strong data-start=\"7657\" data-end=\"7669\">voltaggio:<\/strong> 347\/600 Volt trifase<br data-start=\"7691\" data-end=\"7694\" \/><strong data-start=\"7694\" data-end=\"7709\">Ampere nominali:<\/strong> 121 Ampere<br data-start=\"7718\" data-end=\"7721\" \/><strong data-start=\"7721\" data-end=\"7735\">Frequenza:<\/strong> 60 Hz<\/p>","protected":false},"featured_media":11015,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[126,128],"product_tag":[],"class_list":{"0":"post-11016","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-commercial-generators","7":"product_cat-kohler-commercial-generators","9":"first","10":"instock","11":"taxable","12":"shipping-taxable","13":"purchasable","14":"product-type-simple"},"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/bootsshopbodensee.com\/it\/wp-json\/wp\/v2\/product\/11016","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bootsshopbodensee.com\/it\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/bootsshopbodensee.com\/it\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/bootsshopbodensee.com\/it\/wp-json\/wp\/v2\/comments?post=11016"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bootsshopbodensee.com\/it\/wp-json\/wp\/v2\/media\/11015"}],"wp:attachment":[{"href":"https:\/\/bootsshopbodensee.com\/it\/wp-json\/wp\/v2\/media?parent=11016"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/bootsshopbodensee.com\/it\/wp-json\/wp\/v2\/product_brand?post=11016"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/bootsshopbodensee.com\/it\/wp-json\/wp\/v2\/product_cat?post=11016"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/bootsshopbodensee.com\/it\/wp-json\/wp\/v2\/product_tag?post=11016"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}